logo
뉴스
> 뉴스 > 회사 뉴스 정보 95kPa Specimen Transport Bags for UN3373 Category B Biological Substances
행사
저희와 연락
+86-551-6468-7322
지금 연락하세요

95kPa Specimen Transport Bags for UN3373 Category B Biological Substances

2026-05-13

에 대한 최신 회사 뉴스 95kPa Specimen Transport Bags for UN3373 Category B Biological Substances

When shipping Category B biological substances (UN3373) by air or road, regulatory compliance is mandatory. A 95kPa specimen transport bag plays a critical role in the triple packaging system under IATA Packing Instruction 650 and P650, serving as leakproof secondary packaging that must withstand an internal pressure differential of 95 kPa without leakage. Independent third-party testing is the only reliable way to verify true 95kPa capability.

What Is a 95kPa Specimen Transport Bag?

UN3373 refers to Biological Substances, Category B – infectious materials that do not meet the risk threshold of Category A (which are capable of causing life-threatening infections). These substances fall under Hazard Class 6.2 and include blood samples for diagnostic testing, tissue specimens, urine samples, nasal swabs, and other human or animal body fluids collected for research or clinical purposes. Category B substances are regulated under IATA PI650 (air), P650 (ADR road), and DOT 49 CFR 173.199 (U.S.), and must be transported in packaging that meets strict performance criteria.

A 95kPa specimen bag is a leakproof, puncture-resistant secondary packaging solution specifically designed to contain the primary receptacle (sample tube) and provide an additional barrier against leaks or contamination. The “95kPa” designation refers to the bag’s tested ability to withstand an internal pressure differential of 95 kilopascals (approximately 0.95 bar) without leakage, as required by Packing Instruction P650 and IATA PI650 for liquid substances.

Key Regulatory Standards and Guidance Documents

Compliance with multiple regulatory frameworks is essential for UN3373 shipments. The table below outlines the key standards:

 
 
Standard / Regulation Description Jurisdiction / Mode
IATA Packing Instruction 650 (PI650) Primary regulation for air transport of Category B UN3373 substances; specifies triple packaging, 95kPa pressure requirement, and marking/labeling International Air Transport
ADR P650 (Road Transport) European Agreement concerning the International Carriage of Dangerous Goods by Road; packaging instruction for Category B specimens Road (Europe & international)
DOT 49 CFR §173.199 U.S. Department of Transportation regulation for Category B infectious substances; requires leakproof packaging and 95kPa capability for secondary packaging United States (all modes)
IMDG Code (Maritime) International Maritime Dangerous Goods Code for sea transport of dangerous goods Sea / Vessel
UN3373 Marking Diamond-shaped hazard mark (minimum 50mm side length at 45° angle) with text “Biological Substance, Category B” (minimum 6mm high) All transport modes
ICAO Technical Instructions International Civil Aviation Organization’s detailed regulations for air transport of dangerous goods; forms basis for IATA DGR International Air

The 95kPa Pressure Requirement: Why It Matters

Under Packing Instruction P650 (IATA & IMDG) and DOT 49 CFR 173.199 for UN3373 Category B liquid substances, either the primary receptacle or the secondary packaging must withstand an internal pressure of 95 kPa (kilopascals) without leakage. This pressure requirement is not arbitrary—it simulates the pressure differentials that can occur during transportation due to altitude changes (especially during air freight), temperature variations, and mechanical handling.

For air transport, the 95kPa test must be conducted not only at ambient temperature but also at -40°C and +55°C to account for extreme temperature conditions experienced in aircraft cargo holds and ground transportation. A biohazard bag that fails this pressure test creates potentially serious risks, including leakage of infectious materials, contamination of couriers and laboratory personnel, and shipment rejection leading to regulatory non-compliance.

The Triple Packaging System Under P650 / PI650

To legally ship UN3373 substances, a triple packaging system is required. This consists of three essential components:

  1. Primary Receptacle (Leakproof) – The innermost container that directly holds the biological substance (e.g., a test tube with a screw cap or positive closure). For liquids, it must be leakproof; for solids, siftproof. Multiple fragile primary receptacles placed in a single secondary packaging must be individually wrapped or separated to prevent contact.

  2. Secondary Packaging (Leakproof) – This is where the 95kPa specimen bag functions as a compliant secondary leakproof container. The secondary packaging must be leakproof for liquids and siftproof for solids. Either the primary receptacle or the secondary packaging must be capable of withstanding the 95kPa internal pressure without leakage for liquid substances. Absorbent material (sufficient to absorb the entire liquid contents of all primary receptacles) must be placed between the primary and secondary packaging.

  3. Rigid Outer Packaging – Must be of adequate strength for its capacity, mass, and intended use. At least one surface must have minimum dimensions of 100mm x 100mm. An itemized list of contents must be enclosed between the secondary and outer packaging. The complete package must be capable of passing a 1.2m drop test without leakage. The outer packaging must display the UN3373 diamond-shaped mark and the words “BIOLOGICAL SUBSTANCE, CATEGORY B” in letters at least 6mm high.

For transport within the United States, DOT 49 CFR 173.199 requires that when a secondary packaging (such as a 95kPa bag) is used as the leakproof containment layer, it must meet the same pressure and leakproofness standards as any other compliant packaging solution. The rigid outer packaging must also withstand the 1.2m drop test and maintain structural integrity throughout transit.

Documentation, Labeling, and Quantity Limits

Proper documentation and labeling are mandatory for UN3373 shipments. An Air Waybill (AWB) must clearly state ‘UN3373 Biological Substance, Category B’ and the number of packages. The name and phone number of a responsible person must be included on the package or the AWB.

Quantity limits apply: for liquids, each primary receptacle is limited to a maximum of 1 liter, and the total volume per outer package must not exceed 4 liters. For solids (excluding body parts, organs, or whole bodies), the outer package must not contain more than 4 kg. These quantity limits exclude ice, dry ice, or liquid nitrogen when used as refrigerants.

Compliance with Packing Instruction 650 (IATA) exempts shippers from formal Dangerous Goods declarations, provided all packaging and labeling requirements are met. For Category B transport by road, UN3373 compliance requires the leakproof primary container to be held in a secondary leakproof container, with one of these passing the 95kPa pressure test.

Features of a Compliant 95kPa Specimen Bag

A genuinely compliant 95kPa specimen bag should demonstrate the following characteristics, ideally verified through independent third-party laboratory testing:

 
 
Feature Purpose / Benefit
Independent 95kPa pressure testing Verifies genuine capability; suppliers should provide test certificates
Leakproof and puncture-resistant construction Prevents leakage of infectious materials and contamination
Strong waterproof adhesive closure Ensures secure sealing and tamper evidence
Integrated document pouch Keeps paperwork separate, traceable, and contamination-free
Unique barcode for traceability Supports patient/specimen identification and chain of custody
Easy open tear notches Enables quick access at the receiving lab without scissors
Clear biohazard and UN3373 markings Visual compliance for handlers at all stages
Available in multiple sizes Accommodates different primary receptacle volumes
Compatible with rigid outer boxes Integrates seamlessly into complete UN3373 shipping kits

Applications and End-Users

95kPa specimen transport bags are trusted by a wide range of facilities worldwide for the secure handling of biohazardous materials, including laboratories, hospitals, diagnostic centers, veterinary clinics, biotech companies, and medical research facilities. Common applications include routine diagnostic sample transportation, clinical trial specimen logistics, veterinary sample shipping, research specimen transfer, infectious disease monitoring, and public health surveillance.

Risks of Non-Compliance

Using specimen bags that have not been independently tested and certified to 95kPa creates significant risks. If a bag fails the pressure test, sample leakage can occur during transport, endangering handlers and contaminating vehicles or facilities. Shipments may be rejected by carriers or flagged for regulatory non-compliance, leading to operational delays and potential legal consequences. Regulatory authorities are increasingly scrutinizing UN3373 compliant packaging, making independent verification essential.

How to Verify 95kPa Capability

Any supplier claiming 95kPa performance should be able to provide verifiable documentation, including:

  • A 95kPa test certificate from an independent, accredited test laboratory

  • Details of test conditions (pressure applied, duration, temperature range)

  • Batch/lot traceability linking test certificates to specific product batches

If this documentation is not readily available, the bag’s claimed 95kPa capability should be considered unverified.

문의사항을 직접 저희에게 보내세요

개인정보 보호 정책 중국 좋은 품질 95Kpa 부대 공급자. 저작권 2019-2026 95kpa-bags.com . 무단 복제 금지.